We've detected that you're using an ad content blocking browser plug-in or feature. Ads provide a critical source of revenue to the continued operation of Silicon Investor.  We ask that you disable ad blocking while on Silicon Investor in the best interests of our community.  If you are not using an ad blocker but are still receiving this message, make sure your browser's tracking protection is set to the 'standard' level.
Technology Stocks : Intel Corporation (INTC)
INTC 37.81-4.3%Dec 12 9:30 AM EST

 Public ReplyPrvt ReplyMark as Last ReadFilePrevious 10Next 10PreviousNext  
To: Robert Salasidis who wrote (148899)11/20/2001 11:15:08 AM
From: Ali Chen  Read Replies (1) of 186894
 
Robert, "TjMax (junction not case) is defined on page 71 as 100 deg C as measure by the on die thermal diode...
However by my reading of the datasheets, Intel's measurements are made at junction temperature of 100 deg C "

Please stop your nonsense about 100C on Intel mobile parts
in deep sleep state. Look into the same Table 41 you
just quoted, right-most column called "Notes".
It says: both deep and "deeper" sleep modes were
measured at 35C.

ftp://download.intel.com/design/mobile/datashts/29834002.pdf
The last line in the Table 41 is the specification for
Tj, which can be anywhere from 0 to 100C, and has
nothing to do with other specific specifications listed
in other lines of the Table 41.

It is amazing how selective could people be.

- Ali