We've detected that you're using an ad content blocking browser plug-in or feature. Ads provide a critical source of revenue to the continued operation of Silicon Investor.  We ask that you disable ad blocking while on Silicon Investor in the best interests of our community.  If you are not using an ad blocker but are still receiving this message, make sure your browser's tracking protection is set to the 'standard' level.
Biotech / Medical : ARADIGM CORP. ARDM

 Public ReplyPrvt ReplyMark as Last ReadFilePrevious 10Next 10PreviousNext  
To: tuck who wrote (180)10/13/2003 7:49:02 PM
From: tuck  Read Replies (1) of 255
 
>>J Clin Pharmacol. 2003 Nov;43(11):1228-34.

Young and Elderly Type 2 Diabetic Patients Inhaling Insulin with the AERx(R) Insulin Diabetes Management System: A Pharmacokinetic and Pharmacodynamic Comparison.

Henry RR, Mudaliar S, Chu N, Kim D, Armstrong D, Davis TT, An B, Reinhardt RR.

Section of Diabetes/Endocrinology, VA San Diego Healthcare System, 3350 La Jolla Village Dr. (111G), San Diego, CA 92161.

The objective of this study was to compare the pharmacokinetics (PK), pharmacodynamics (PD), and safety of inhaled insulin delivered by the AERx(R) iDMS in young and elderly patients with type 2 diabetes. Twenty-seven young (18-45 years, inclusive) and 28 elderly (>/= 65 years) type 2 diabetic patients were enrolled in this study. A single inhalation of 1.57 mg (45 IU, effect comparable to 6 s.c. units) of regular human insulin was administered to each patient on each of 2 dosing days, and blood samples were drawn up to 360 minutes postdosing to generate the PK/PD curves. AUC(0-360 min) and Cmax values of inhaled insulin were comparable between young and elderly subjects (p = 0.476 for AUC(0-360 min) and p = 0.414 for Cmax). However, the elderly group had significantly less glucose reduction, as indicated by plasma glucose AOC(0-360) (area over the curve) values (p = 0.011). The intrasubject variability of inhaled insulin using the AERx(R) iDMS was similar for young and elderly subjects and was similar to what has previously been reported for soluble insulin administered subcutaneously. Inhaled insulin was well tolerated in these patients, and no changes in pulmonary function tests were observed. A single inhalation of insulin using the AERx(R) iDMS demonstrated comparable insulin PK profiles between the elderly and young type 2 patients but less glucose reduction in the elderly. Based on these results, elderly diabetic patients may need to inhale more insulin than young patients to achieve similar glycemic control. Long-term clinical trials using the AERx(R) device will be useful to study age-related differences.<<

This institution recently published an article on AeroGen's system, too. They seem to be very active in this arena.