We've detected that you're using an ad content blocking browser plug-in or feature. Ads provide a critical source of revenue to the continued operation of Silicon Investor.  We ask that you disable ad blocking while on Silicon Investor in the best interests of our community.  If you are not using an ad blocker but are still receiving this message, make sure your browser's tracking protection is set to the 'standard' level.
Politics : Formerly About Advanced Micro Devices

 Public ReplyPrvt ReplyMark as Last ReadFilePrevious 10Next 10PreviousNext  
To: Tenchusatsu who wrote (65043)7/13/1999 11:05:00 AM
From: Ali Chen  Read Replies (1) of 1580052
 
<What's the EV6's common clock rate, and what's its actual transfer rate for requests and data?>
For current K7 systems the clock is 100MHz while data and
requests/addresses are running at 200MHz - at both
falling and rising clock edges. For Aplha/Tsunami systems
the clock is currently 150MHz, with 300MHz data/request rate.