We've detected that you're using an ad content blocking browser plug-in or feature. Ads provide a critical source of revenue to the continued operation of Silicon Investor.  We ask that you disable ad blocking while on Silicon Investor in the best interests of our community.  If you are not using an ad blocker but are still receiving this message, make sure your browser's tracking protection is set to the 'standard' level.
Technology Stocks : AMD/INTC/RMBS et ALL

 Public ReplyPrvt ReplyMark as Last ReadFilePrevious 10Next 10PreviousNext  
To: kash johal who wrote (145)10/1/1999 1:22:00 AM
From: grok  Read Replies (1) of 271
 
No, you missed my point. The normal Rambus method requires continuity modules to carry the traces over unused slots in order to get the traces to the termination resistors at the far end (beyond the 3rd slot).

But the fix that Petz suggested to the problem of not be able to tolerate a 3rd slot even if it is unused is to fill it with a discontinuity modules that has only the resistors on it. So this module electrically removes the 3rd slot without requiring rework of the board.

However, due to articles that have hit the web tonight I suspect that the problems may be more severe than could be fixed by removing a slot.