We've detected that you're using an ad content blocking browser plug-in or feature. Ads provide a critical source of revenue to the continued operation of Silicon Investor.  We ask that you disable ad blocking while on Silicon Investor in the best interests of our community.  If you are not using an ad blocker but are still receiving this message, make sure your browser's tracking protection is set to the 'standard' level.
Technology Stocks : Nokia (NOK)
NOK 6.965+0.8%12:37 PM EST

 Public ReplyPrvt ReplyMark as Last ReadFilePrevious 10Next 10PreviousNext  
To: S100 who wrote (18640)3/6/2002 2:17:08 PM
From: S100  Read Replies (1) of 34857
 
Power use in the phone, draws one half amp at times, no wonder the battery life on amps on all phones is so bad.

DC Currents in the RF stage
( All Currents measured are RMS values in milliamperes)
Low band TDMA
Power Levels Lowest Channel ( # 991) Mid Channel ( # 383) Highest Channel (# 799)
2 202 ma 198 ma 197 ma
3 137 ma 138 ma 122 ma
4 93 ma 94 ma 85 ma
5 51 ma 52 ma 46 ma
6 35 ma 36 ma 33 ma
7 26 ma 27 ma 27 ma
8 20 ma 19 ma 18 ma
9 17 ma 17 ma 15 ma
10 16 ma 16 ma 14 ma
High Band TDMA
Power Levels Lowest Channel ( # 2) Mid Channel ( # 1000) Highest Channel (# 1998)
2 220 ma 218 ma 242 ma
3 158 ma 147 ma 143 ma
4 117 ma 111 ma 108 ma
5 65 ma 59 ma 58 ma
6 46 ma 43 ma 42 ma
7 38 ma 37 ma 37 ma
8 20 ma 19 ma 19 ma
9 17 ma 17 ma 17 ma
10 15 ma 15 ma 15 ma
Low Band AMPS
Power Levels Lowest Channel ( #991) Mid Channel (# 383) Highest Channel ( # 799)
2 593 ma 570 ma 561 ma
3 397 ma 396 ma 358 ma
4 274 ma 274 ma 247 ma
5 156 ma 156 ma 141 ma
6 114 ma 114 ma 106 ma
7 87 ma 87 ma 83 ma
Report TOU ViolationShare This Post