We've detected that you're using an ad content blocking browser plug-in or feature. Ads provide a critical source of revenue to the continued operation of Silicon Investor.  We ask that you disable ad blocking while on Silicon Investor in the best interests of our community.  If you are not using an ad blocker but are still receiving this message, make sure your browser's tracking protection is set to the 'standard' level.
Technology Stocks : General Lithography

 Public ReplyPrvt ReplyMark as Last ReadFilePrevious 10Next 10PreviousNext  
To: WALLY THE SANDCRAB who wrote (474)7/17/1997 10:20:00 AM
From: Yousef   of 1305
 
Wally,

Re: "using i-line
steppers as mix and match for non-critical layers. "

I-Line tools will be used for the non-critical and some "near critical"
layers in a .25um process. Let me explain, a critical layer exists because
of either the need for minimum resolution or tight alignment tolerances. So for Poly, Contact, Metal 1, and Via 1, these require
both narrow lines/spaces and tight alignment. Island/Trench needs to
be critical for the narrow spaces (trenches). All the other ~14 Mask
layers have more relaxed resolution but some of them require fairly
tight alignment. When this occurs, the matching of steppers OR stepper-to-scanner is an important issue. Only vendors that make both
DUV and I-Line will give specs for matching THEIR equipment only. If
you want to match a Nikon with an Ultratech, then you are on your own.
Most Fabs will want to stay with their DUV vendor's I-Line tool for
this reason (as well as lower COO by working with same vendor ...).
Since SVGL doesn't make I-Line tools then, this might be an opportunity
for UTEK. In Intel's case, they match SVGL with I-Line Nikons.