SI
SI
discoversearch

We've detected that you're using an ad content blocking browser plug-in or feature. Ads provide a critical source of revenue to the continued operation of Silicon Investor.  We ask that you disable ad blocking while on Silicon Investor in the best interests of our community.  If you are not using an ad blocker but are still receiving this message, make sure your browser's tracking protection is set to the 'standard' level.
Biotech / Medical : Ciphergen Biosystems(CIPH):

 Public ReplyPrvt ReplyMark as Last ReadFilePrevious 10Next 10PreviousNext  
To: tuck who wrote (156)10/9/2003 1:55:26 PM
From: tuck  Read Replies (1) of 510
 
[identifying the proteins fingerprinted by SELDI]

>>Anal Biochem. 2003 Oct 1;321(1):116-24.

Methods for on-chip protein analysis.

Caputo E, Moharram R, Martin BM.

Unit on Molecular Structures, LNT, NIMH, NIH, DHHS, 10 Center Drive, Bldg. 10 3N309, Bethesda, MD 20892-1262, USA.

The unambiguous identification of peptides/proteins is crucial for the definition of the proteome. Using ProteinChip Array technology also known as surface-enhanced laser desorption/ionization-time of flight mass spectrometry (SELDI-TOF MS), we developed experimental protocols and probed test conditions required for the protein identification on ProteinChip surfaces. We were able to directly digest peptides/proteins on-chip surfaces by specific proteases, such as trypsin, and to obtain the peptide mass fingerprint of the sample under investigation by its direct analysis on a simple laser desorption/ionization mass spectrometer. Furthermore, tandem mass spectrometry was performed on several of the resulting tryptic peptides by using collision quadrupole time of flight (Qq-TOF) MS/MS via the ProteinChip interface, thus allowing the unambiguous identification of the protein(s) within the sample. In addition, we were able to identify the C-terminal sequence of peptides by their digestion with carboxypeptidase Y directly on ProteinChip surfaces coupled with SELDI-TOF MS analysis of the resulting peptide mass ladders employing the instrument's protein ladder sequence software. Moreover, the removal of up to nine amino acid residues from the C-terminal end of a peptide extends the functional range of Qq-TOF MS/MS sequence determination to over 3000 m/z. The utility of these procedures for the proteome exploration are discussed.<<

Cheers, Tuck
Report TOU ViolationShare This Post