SI
SI
discoversearch

We've detected that you're using an ad content blocking browser plug-in or feature. Ads provide a critical source of revenue to the continued operation of Silicon Investor.  We ask that you disable ad blocking while on Silicon Investor in the best interests of our community.  If you are not using an ad blocker but are still receiving this message, make sure your browser's tracking protection is set to the 'standard' level.
Biotech / Medical : ARADIGM CORP. ARDM

 Public ReplyPrvt ReplyMark as Last ReadFilePrevious 10Next 10PreviousNext  
To: tuck who wrote (190)3/30/2004 9:49:01 AM
From: tuck  Read Replies (2) of 255
 
While we wait for Godot . . .

>>Diabetes. 2004 Apr;53(4):877-81.

Inhalation of insulin in dogs: assessment of insulin levels and comparison to subcutaneous injection.

Cherrington AD, Neal DW, Edgerton DS, Glass D, Bowen L, Hobbs CH, Leach C, Rosskamp R, Strack TR.

Vanderbilt University Medical Center, Nashville, Tennessee. Lovelace Respiratory Research Institute, Albuquerque, New Mexico. Nektar Therapeutics, San Carlos, California. Aventis, Bridgewater, New Jersey. Pfizer, New York, New York.

Pulmonary insulin delivery is being developed as a more acceptable alternative to conventional subcutaneous administration. In 15 healthy Beagle dogs (average weight 9.3 kg), we compared insulin distribution in arterial, deep venous, and hepatic portal circulation. Dogs received 0.36 units/kg s.c. regular human insulin (n = 6) or 1 mg (2.8 units/kg) or 2 mg (5.6 units/kg) dry-powder human inhaled insulin (n = 3 and 6, respectively). Postinhalation of inhaled insulin (1 or 2 mg), arterial insulin levels quickly rose to a maximum of 55 +/- 6 or 92 +/- 9 micro U/ml, respectively, declining to typical fasting levels by 3 h. Portal levels were lower than arterial levels at both doses, while deep venous levels were intermediate to arterial and portal levels. In contrast, subcutaneous insulin was associated with a delayed and lower peak arterial concentration (55 +/- 8 micro U/ml at 64 min), requiring 6 h to return to baseline. Peak portal levels for subcutaneous insulin were comparable to those for 1 mg and significantly less than those for 2 mg inhaled insulin, although portal area under the curve (AUC) was comparable for the subcutaneous and 2-mg groups. The highest insulin levels with subcutaneous administration were seen in the deep venous circulation. Interestingly, the amount of glucose required for maintaining euglycemia was highest with 2 mg inhaled insulin. We conclude that plasma insulin AUC for the arterial insulin level (muscle) and hepatic sinusoidal insulin level (liver) is comparable for 2 mg inhaled insulin and 0.36 units/kg subcutaneous insulin. In addition, arterial peak concentration following insulin inhalation is two times greater than subcutaneous injection; however, the insulin is present in the circulation for half the time.<<

Cheers, Tuck
Report TOU ViolationShare This Post
 Public ReplyPrvt ReplyMark as Last ReadFilePrevious 10Next 10PreviousNext