We've detected that you're using an ad content blocking browser plug-in or feature. Ads provide a critical source of revenue to the continued operation of Silicon Investor.  We ask that you disable ad blocking while on Silicon Investor in the best interests of our community.  If you are not using an ad blocker but are still receiving this message, make sure your browser's tracking protection is set to the 'standard' level.
Politics : Rat's Nest - Chronicles of Collapse

 Public ReplyPrvt ReplyMark as Last ReadFilePrevious 10Next 10PreviousNext  
To: SiouxPal who wrote (30)5/7/2005 5:59:06 PM
From: Wharf Rat  Read Replies (1) of 24210
 
One more cost, if you are going to interface with the grid, which means you don't need batteries; an inverter...

(From 101 reasons why a zapsucker is as good as a Ratzinger)

UTILITY INTERFACE CATALOG

HOW TO SIZE YOUR UTILITY INTERFACE SYSTEM
Get your utility bill. Make sure it's your electric service only, not the gas service.
Now fill in the blanks below.
Usage_______Billing Days_________Divide Usage by Billing Days_________
This is your average daily Kw hr usage. Divide this by 5 (average sun hours in most areas of California). This is the size of sytem you need to eliminate your electric bill.

Example:
Usage=1,130kWH
Billing Days=30
Divide Usage by Billing Days=37.66 kWh per day on average.
Divide this by 5 = 7.53kW System

Therefore combining our 5.035 system with a 2.5 system (see below) will total 7.535 kW and will eliminate your electric utility bill. If you have questions don't hesitate to call us at 888-228-9694 (toll free) or 707-485-0588.

UTILITY INTERFACE SYSTEMS
1. ALL SYSTEMS QUOTED ARE BASED ON CEC RATED OUTPUT.
2. ALL SYSTEMS QUOTED INCLUDE AT LEAST 2 SOLAR PANEL HIGH VOLTAGE DISCONNECTS (OUTDOOR, 30 AMP AT 600VDC). MOST MUNICIPALITIES NOW REQUIRE DISCONNECTS ON THE ROOF (FIRE DEPARTMENT) AND AT THE INVERTERS (SERVICE DISCONNECT).
3. ALL SYSTEMS QUOTED INCLUDE THE REQUIRED UTILITY DISCONNECT
4. ALL SYSTEMS QUOTED INCLUDE SMA INVERTERS WITH DISPLAY (SBD).
5. MOUNTING SPECIFICATIONS QUOTED ARE FULLY ENGINEERED FOR 50 LBS PER SQ FT AND 125 MPH WIND. ENGINEERING SPECIFICATIONS AVAILABLE UPON REQUEST. WE CANNOT QUOTE YOU THE EQUIPMENT NEEDED TO MOUNT THE RAIL SYSTEM ON YOUR ROOF UNTIL WE KNOW WHAT KIND OF ROOF YOU HAVE. FOR MORE INFORMATION SCROLL DOWN TO "UTILITY INTERFACE COMPONENTS" ON THIS PAGE FOR "SOLAR MOUNTING KITS" & "SYSTEM INSTALLATION". WE ALSO HAVE GROUND MOUNTS AVAILABLE.

Solar Utility Interface Systems listed below can be installed in any combination to fulfill your energy needs. Please call if you don't see what you need. 888-228-9694 (toll free) or 707-485-0588.

SMA INVERTER SYSTEMS:

654.7 Watt System - 3.27 kWh per day: $5,948.00
10 KC 80 watt solar panels
1 700 watt SMA Inverter
3 Roof Track Systems
Our crew installation costs average under $1000.00
Based on $2.80 per watt rebate, this system is eligible for a maximum rebate of $1,833.16

1.24 kW System - 6.22 kWh per day: $7,480.00
8 KC 187 watt solar panels
1 1100 watt SMA Inverter
3 Roof Track Systems
Our crew installation costs average under $1500.00
Based on $2.80 per watt rebate, this system is eligible for a maximum rebate of $3,487.27

1.55 kW System - 7.784 kWh per day: $8,968.00
10 KC 187 watt solar panels
1 1800 watt SMA Inverter
4 Roof Track Systems
Our crew installation costs average under $2000.00
Based on $2.80 per watt rebate, this system is eligible for a maximum rebate of $4,687.20

2.5 kW System - 12.5 kWh per day: $13,448.00
16 KC 187 watt solar panels
1 2500 watt SMA Inverter
6 Roof Track Systems
Our crew installation costs average under $3000.00
Based on $2.80 per watt rebate, this system is eligible for a maximum rebate of $7,00.00

5.035 kW System - 25.126 kWh per day: $25,750.00
32 KC 187 watt solar panels
1 6000 watt SMA Inverter
11 Roof Track Systems
Our crew installation costs average under $6000.00
Based on $2.80 per watt rebate, this system is eligible for a maximum rebate of $14,098.00

XANTREX GT 3.0 INVERTER SYSTEMS:

3 kW System - 15 kWh per day: $15,928.00
20 KC 187 watt solar panels
1 3000 watt Xantrex GT 3.0 Inverter
7 Roof Track Systems
Our crew installation costs average under $4000.00
Based on $2.80 per watt rebate, this system is eligible for a maximum rebate of $8,400.00

UTILITY INTERFACE COMPONENTS

INVERTERS:
SMA INVERTERS:
MPPT tracking. Sunny Central and 6000 are active cooling. All other units passive cooling. Optional fan kit is available. Can be mounted indoor or outdoor. LCD display lists daily power production, PV array voltage, MMPT tracking, Grid current, voltage and frequency, Power fed to grid, PV earth fault, PV current and total operational hours. Multiple SMA inverters can be installed in one system. 5 year warranty. For more information go to www.sma-america.com.

SMA SWR 6000U 208,240 & 280 VAC field stable, 60 Hz, input voltage 207-600 vdc

SMA SWR 2500U SBD: 2500 watts, 240 vac, 60 Hz, input voltage 275-550 vdc

SMA SWR 1800U SBD: 1800 watts, 120 vac, 60 Hz, input voltage 150-400 vdc

SMA SB 1100U SBD: 1100 watts, 120 vac, 60 Hz, input voltage 145-400 vdc

SMA SB 700U SBD: 700 watts, 120 vac, 60 Hz, input voltage 77-250 vdc

XANTREX GT 3.0:

MMPT tracking. Thermal performance is 3 kW up to 30 degrees C and 2.5 kW up to 45 degrees C. Optional fan kit. FCC part B compliant. LCD display lists daily and lifetime energy production, PV array voltage and current, utility voltage and frequency, time online "selling" for the day, and fault messages. PC software for remote monitoring and troubleshooting. Modular design allows inverters to be mounted side by side. Can be mounted indoors or outdoors. 5 year warranty. 5 year extended warranty available.

SOLAR PANELS:
KC 187:

Kyocera advanced cell processing technology and automated production facilities produce a highly efficient multicrystal photovoltaic module. The conversion efficiency of the Kyocera solar cell is 15%. These cells are encapsulated between a tempered glass cover and an EVA back shield to provide maximum protection from the most severe environmental conditions. The entire laminate is installed in an anodized aluminum frame providing structural strength and easy installation. KC 187 modules are equiped with plug in connectors. UL 1703 certified. ISO 9001 and ISO 14001 qualified. 25 year limited warranty. For more information go to kyocerasolar.com or call us at 888-228-9694 (toll free).

SOLAR PANEL MOUNTING KITS FOR KC 187:.
Mounting kits quoted are FASTJACK(tm), with FASTTRACK (tm)rail systems. Made of high quality stainless steel and anodized aluminum. One fasttrack rail system (two rails with appropriate hardware) accommodate 3 KC 187 solar panels. Fasttracks come with hardware to mount on preexisting flat roof, such as asphalt shingles. Other roof styles and new roofs usually need fastjacks to support the rail systems. Fastjacks are machined mounts that bolt right into rafters and come with appropriate Oaty flashing. These are designed to accommodate any roof preexisting or new. These are clip and rail systems very simple to install. If you want to put two rails together you need a "Splice Kit and more panel inter connectors. These mounts are pre-engineered and pass all local codes. For more info go to www.rooftrac.com.

SYSTEM INSTALLATION: We normally have Fast Jacks installed by your roofer. If you do not have a roofer we have roofers in the Bay Area and many parts of California who install Fast Jacks for us (under our guidance).We usually do the layout, they install them (this keeps your roof warrantee intact and virtually eliminates roofing problems). Then, we come on site and install the Fast Track rail system and solar panels. We also have many local electricians help us with system installations. We strive to get as many local companies involved as possible. We are licensed solar and electrical contractors (C-10 and C-46 #620243) and could do all the work ourselves. However, we have found it benificial to involve local reputable companies with expertise in local code compliance, familiarity with local utility regulations and for trouble shooting any system problems. This is a win, win solution for everyone. Customers get local support, plus our years of experience and competitiveness in this industry.

GROUND MOUNTING SYSTEMS:
Ground mounts are engineered for a 6' span. The rails are stronger to accomodate the span. Two rails are mounted on 1 1/4" galvanized steel pipe with stainless steel U bolts. Holleander T's connect the horizontal piping to the vertical pipe "legs" thatare cemented in 1' x 2' holes.
UTILITY DISCONNECT SWITCH: Some utility companies require visually open, lockable knife switch disconnects between the inverter(s) and the service entrance. Multiple inverter systems must be designed and installed to use only one utility disconnect switch.
SQ D. DU221RB, rated for outdoor use, 30A @ 240 vac

SQ D. DU222RB, rated for outdoor use, 60A @ 240 vac

Other Models and sizes available. Call for quote.

CEC PTC RATING:
KYOCERA SOLAR:

KC-187G 167.4, KC-125G 111.8, KC-80 70.4

SMA INVERTER EFFICIENCY:

SUNNY CENTRAL:
125KW 3 PHASE 480 VAC 95%

SUNNY BOY:
SWR-700U SBD, 120 VAC 93%
SWR-1100U SBD, 240 VAC 93%
SWR-1800U SBD, 120 VAC 93%
SWR-2500U SBD, 240 &208 VAC 94%
SB-600U, 208, 240, 280 VAC 94%

XANTREX:
GT 3.0 94%

To calculate the CEC Power Rating, multiply the Solar Panel PTC Rating by the number of panels. Multiply this result by the Inverter Efficiency. This gives you the CEC System Power Rating. Multiply this number by 5 (average sun hours) to get the CEC System Daily Power Rating.
To calculate the system maximum rebate multiply the CEC System Power Rating (solar panel PTC rating x number of panels x inverter efficiency) times the rebate amount(now $2.80 per watt).

We Test All Our Products
And Use Them at Our Home and Business
All Prices are Subject to Change

zapsucker.com
Report TOU ViolationShare This Post