We've detected that you're using an ad content blocking browser plug-in or feature. Ads provide a critical source of revenue to the continued operation of Silicon Investor.  We ask that you disable ad blocking while on Silicon Investor in the best interests of our community.  If you are not using an ad blocker but are still receiving this message, make sure your browser's tracking protection is set to the 'standard' level.
Technology Stocks : Cymer (CYMI)

 Public ReplyPrvt ReplyMark as Last ReadFilePrevious 10Next 10PreviousNext  
To: Tim Bagwell who wrote (4722)10/7/1997 11:32:00 PM
From: Si Eng.   of 25960
 
The vibration problems are NOT site related at all. The vibration issue IS STILL a problem and it's with the laser chamber itself. The blower motor spins at about 3,300 RPM's. If the bearings are not set up correctly or are old, they will cause vibration and cause low energy, which in turn ramps up the operating voltage of the laser. It does not vibrate the beam into the stepper/scanner. Cymer's new chamber is modified for better vibration isolation but we still had to replace one of those new chambers after only 5 weeks in use. Lucky for us the two chambers we had replaced were still under warranty.