We've detected that you're using an ad content blocking browser plug-in or feature. Ads provide a critical source of revenue to the continued operation of Silicon Investor.  We ask that you disable ad blocking while on Silicon Investor in the best interests of our community.  If you are not using an ad blocker but are still receiving this message, make sure your browser's tracking protection is set to the 'standard' level.
Biotech / Medical : Caprius(CAPR), Breast MRI(former ANMR/MAMO)
CAPR 5.620-2.6%Nov 14 9:30 AM EST

 Public ReplyPrvt ReplyMark as Last ReadFilePrevious 10Next 10PreviousNext  
To: luis a. garcia who wrote (2133)11/11/1997 11:17:00 PM
From: Zeev Hed  Read Replies (1) of 2615
 
Luis, just one note, it is the same PPM difference between the different intensities (the Larmor frequency itself increases with the field intesity). You go to higher field since the frequency is higher and fortunately, frequency "tuning" (or descrimination) can be detected to few hertz or tens of hertz (deppnding a lot on a bunch of other things).

Zeev