We've detected that you're using an ad content blocking browser plug-in or feature. Ads provide a critical source of revenue to the continued operation of Silicon Investor.  We ask that you disable ad blocking while on Silicon Investor in the best interests of our community.  If you are not using an ad blocker but are still receiving this message, make sure your browser's tracking protection is set to the 'standard' level.
Politics : Formerly About Advanced Micro Devices

 Public ReplyPrvt ReplyMark as Last ReadFilePrevious 10Next 10PreviousNext  
Recommended by:
locogringo
To: Taro who wrote (1212696)3/25/2020 1:05:24 AM
From: FJB1 Recommendation   of 1577179
 
Mechanical Ventilator Milano (MVM): A Novel Mechanical Ventilator Designed for Mass Scale Production in Response to the COVID-19 Pandemics

C. Galbiati, W. Bonivento, M. Caravati, S. De Cecco, T. Dinon, G. Fiorillo, D. Franco, F. Gabriele, C. L. Kendziora, I. Kochanek, An. Ianni, A. McDonald, L. Molinari Tosatti, M. Malosio, D. Minuzzo, S. H. Pordes, A. Prini. A. Razeto, M. Razeti, M. Rescigno, D. Sablone, E. Scapparone, G. Testera, R. Tartaglia, H. Wang, A. Zardoni
(Submitted on 23 Mar 2020)
We present here the design of the Mechanical Ventilator Milano (MVM), a novel mechanical ventilator designed for mass scale production in response to the COVID-19 pandemics, to compensate for the dramatic shortage of such ventilators in many countries. This ventilator is an electro-mechanical equivalent of the old, reliable Manley Ventilator. Our design is optimized to permit large sale production in short time and at a limited cost, relying on off-the-shelf components, readily available worldwide from hardware suppliers. Operation of the MVM requires only a source of compressed oxygen (or compressed medical air) and electrical power. The MVM control and monitoring unit can be connected and networked via WiFi so that no additional electrical connections are necessary other than the connection to the electrical power.
At this stage the MVM is not a certified medical device. Construction of the first prototypes is starting with a team of engineers, scientists and computing experts. The purpose of this paper is to disseminate the conceptual design of the MVM broadly and to solicit feedback from the scientific and medical community to speed the process of review, improvement and possible implementation.


Subjects: Medical Physics (physics.med-ph)
Cite as: arXiv:2003.10405 [physics.med-ph]
(or arXiv:2003.10405v1 [physics.med-ph] for this version)




Bibliographic data

[Enable Bibex ( What is Bibex?)]

Submission history From: Walter Bonivento [ view email]
[v1] Mon, 23 Mar 2020 17:30:06 UTC (1,788 KB)
Report TOU ViolationShare This Post
 Public ReplyPrvt ReplyMark as Last ReadFilePrevious 10Next 10PreviousNext