SI
SI
discoversearch

We've detected that you're using an ad content blocking browser plug-in or feature. Ads provide a critical source of revenue to the continued operation of Silicon Investor.  We ask that you disable ad blocking while on Silicon Investor in the best interests of our community.  If you are not using an ad blocker but are still receiving this message, make sure your browser's tracking protection is set to the 'standard' level.
Gold/Mining/Energy : Global Platinum & Gold (GPGI)

 Public ReplyPrvt ReplyMark as Last ReadFilePrevious 10Next 10PreviousNext  
To: Richard Mazzarella who wrote (5997)5/23/1998 12:05:00 AM
From: Chuca Marsh  Read Replies (1) of 14226
 
Here is park of what Chuck B at IPM/MXAM/&GPGI on occasion threads/ers found on resins last month, I lost the link.:
THE GOLD RECOVERY MODULE
>> MONEY IN YOUR POCKET, NOT IN
>> YOUR DRAIN
>>
>>
>>
>>The Remco Engineering Gold recovery module puts money in your pocket, not
>>in your
>>drain. If you don't have an ion exchange recovery module on your Gold
>>rinse, you are
>>rinsing money down the drain. Many shops have plate-out units on their Gold
>> dragouts,
>>but Gold is still rinsed down the drain. Plate out units only work down to
>>50-200 ppm. Ion
>>exchange systems work down to 10-50 parts per BILLION. Our system uses
>>multiple
>>columns to provide a long path length and a long residence time in a
>>compact unit.
>>
>>Our system features its own containment system in case there is a leak in
>>the connections
>>so no Gold is dumped on the floor. The columns are easily emptied and
>>refilled with new
>>resin. Used resin is sent to a reclaimer to be burned. By using 3 small
>>columns in series,
>>only the first column needs to fill before reclaiming. This minimizes your
>>Gold inventory
>>awaiting reclaim. After the first column is emptied of resin, it is
>>refilled and moved to the
>>end of the line to be the final polishing filter.
>>
>>The system mounts directly to the top flange of the rinse tank. We
>>recommend you use
>>either a small sump pump and recirculate the rinse through the columns at
>>about 0.5 gpm,
>>or you can use our optional level control to operate the pump to feed
>>solution from the
>>rinse to the columns and down the drain.
>>
>> GOLD RECLAIM MODULE SPECIFICATIONS
>>
>>Operational Range:
>>pH......................................................................2-1
>>2
>>
>>Flow rate range:...............................................0-.5 GPM
>>
>>Pump, (customer supplied)
>>Centrifugal........................................................0.5 gpm
>>Tubing...............................................................0-0.5
>>gpm
>>Power................................................................1/6hp
Chucaph2-12
Report TOU ViolationShare This Post
 Public ReplyPrvt ReplyMark as Last ReadFilePrevious 10Next 10PreviousNext