SI
SI
discoversearch

We've detected that you're using an ad content blocking browser plug-in or feature. Ads provide a critical source of revenue to the continued operation of Silicon Investor.  We ask that you disable ad blocking while on Silicon Investor in the best interests of our community.  If you are not using an ad blocker but are still receiving this message, make sure your browser's tracking protection is set to the 'standard' level.
Biotech / Medical : SANGUINE CORP. (SGNC)

 Public ReplyPrvt ReplyMark as Last ReadFilePrevious 10Next 10PreviousNext  
To: Mr. Forthright who wrote (1468)6/20/1998 1:15:00 AM
From: chirodoc  Read Replies (1) of 5402
 
PFC'S WERE DEEMED SAFE IN HUMANS
WHEN USED AS A CONTRAST AGENT (FOR IMAGING)

Invest Radiol 1997 Dec;32(12):735-740

Phase I clinical trials of MRX-115. A new ultrasound contrast agent.

Fritz TA, Unger EC, Sutherland G, Sahn D

ImaRx Pharmaceutical Corp., Tucson, Arizona 85719, USA.

RATIONALE AND OBJECTIVES: Stabilized microbubbles are under development as contrast agents for medical ultrasound. The authors report the results of Phase I clinical trials of a new ultrasound contrast agent based on lipidencapsulated perfluorocarbon gas microbubbles. METHODS: Lipids encapsulating perfluoropropane gas (Aerosomes MRX-115, ImaRx Pharmaceutical Corp., Tucson, AZ) were evaluated in Phase I clinical trials. Two separate studies were performed. The first was a single escalating-dose study (n = 30 subjects), and the second was a multiple-dose study (n = 18 subjects) with rechallenge in several subjects (n = 4) after 21 days. Echocardiographic examinations were performed before and after contrast agent for each test drug administration for both studies, with the exception of the rechallenge group. Doses tested in the single-dose study ranged from 0.005 mL/kg to 0.100 mL/kg body weight. In the multiple-dose study, five doses of 0.005 mL/ kg to 0.030 mL/kg (0.025-0.150 mL/kg total dose) were evaluated. Studies were single-masked, placebo-controlled, and safety assessment and adverse events were monitored. RESULTS: All doses in both studies were well tolerated with no treatment-related changes in safety measures for either study. Left ventricular cavity and myocardial enhancement were seen with all doses of MRX-115. CONCLUSIONS: MRX-115 is a promising new intravascular ultrasound contrast agent that was safe and well tolerated at the doses evaluated in these studies.
Report TOU ViolationShare This Post
 Public ReplyPrvt ReplyMark as Last ReadFilePrevious 10Next 10PreviousNext