SI
SI
discoversearch

We've detected that you're using an ad content blocking browser plug-in or feature. Ads provide a critical source of revenue to the continued operation of Silicon Investor.  We ask that you disable ad blocking while on Silicon Investor in the best interests of our community.  If you are not using an ad blocker but are still receiving this message, make sure your browser's tracking protection is set to the 'standard' level.
Microcap & Penny Stocks : Computerized Thermal Imaging CIO (formerly COII)
CIO 6.955-0.1%Dec 15 3:59 PM EST

 Public ReplyPrvt ReplyMark as Last ReadFilePrevious 10Next 10PreviousNext  
To: Gwolf who wrote (760)7/9/1998 1:10:00 AM
From: chirodoc  Read Replies (1) of 6039
 
THERMAL IMAGING CAN DETECT BRAIN FUNCTION--
BENEATH THE SKULL!

TALK ABOUT A NEEDLE IN A HAYSTACK

NOTE THAT THEY USED A COMPUTERIZED ALGORITHM

ANYONE WHO THINKS THIS TECH WON'T WORK IS CRAZY.

Med Biol Eng Comput 1997 Nov;35(6):587-594

Computerised infrared imaging system for studying thermal activation on the skull following somatic stimulation in small animals.

Wu BM, Lam FK, Chan FH, Poon PW, Brugge JF, Chan JC, So AT

Department of Electrical & Electronic Engineering, University of Hong Kong, Hong Kong.

A computerised infrared imaging system has been developed to measure infrared radiation as a means of functionally mapping the cerebral cortex. In two species of small mammal, rat and gerbil, the authors localised the thermal changes at the skull overlying the somatic sensory cortex following somatic stimulation of the mystacial vibrissae. Though typically small in magnitude, a thermal response could be detected through the skull. To enhance detection sensitivity, a number of measures were taken to improve various aspects of data acquisition, stimulus delivery and control of experimental conditions. Regarding data analysis, a coordinate system based on skull landmarks was adopted to localise thermally-active regions for comparison across animals of the same species. To extract the region of weak temperature changes, a coarse-to-fine detection strategy was developed, which searched automatically for clusters of temporally- and spatially-correlated pixels above a data-driven threshold. Thus, the dynamic aspect of the thermal changes at any region of interest on the skull could be studied efficiently. The detection algorithm was tested against simulated responses in addition to empirical data obtained from animals. All of the above software was integrated in a user-friendly package.
Report TOU ViolationShare This Post
 Public ReplyPrvt ReplyMark as Last ReadFilePrevious 10Next 10PreviousNext