We've detected that you're using an ad content blocking browser plug-in or feature. Ads provide a critical source of revenue to the continued operation of Silicon Investor.  We ask that you disable ad blocking while on Silicon Investor in the best interests of our community.  If you are not using an ad blocker but are still receiving this message, make sure your browser's tracking protection is set to the 'standard' level.
Politics : Formerly About Advanced Micro Devices

 Public ReplyPrvt ReplyMark as Last ReadFilePrevious 10Next 10PreviousNext  
To: Maxwell who wrote (35175)7/29/1998 1:14:00 AM
From: Paul Engel  Read Replies (1) of 1572857
 
Maxwell - Re: " The barrier layer is TaN. The sidewall
coverage is 50A! "

I think you'll find 50 A barrier layers are a disaster.

Most work today uses barrier films (TiN mostly but some use TaN) of 15 to 30 Nanometers = 150 to 300 Angstroms.

Multiplying this by 2 (two sidewalls) and you have 300 to 600 A of an 1800 A (minimum) trench consumed by barrier films.

Hence, 16 to 32% of the THEORETICAL copper line width isn't even copper!

Bye Bye copper advantage!

Paul