We've detected that you're using an ad content blocking browser plug-in or feature. Ads provide a critical source of revenue to the continued operation of Silicon Investor.  We ask that you disable ad blocking while on Silicon Investor in the best interests of our community.  If you are not using an ad blocker but are still receiving this message, make sure your browser's tracking protection is set to the 'standard' level.
Gold/Mining/Energy : PolyMet Mining Corp POM.V (was Fleck Resources)
POM 26.930.0%Apr 1 5:00 PM EST

 Public ReplyPrvt ReplyMark as Last ReadFilePrevious 10Next 10PreviousNext  
To: Shaun M. Dykes who wrote (531)10/9/1998 9:59:00 AM
From: Mr Metals  Read Replies (2) of 708
 
****NEWS RELEASE****

Comments??

Polymet Mining Corp -
Additional assay results from Dunka Road
Polymet Mining Corp POM
Shares issued 13,451,395 1998-10-08 close $1.19
Monday Oct 12 1998

Mr. Donald Gentry reports
The company has received additional results from its 6,365 foot reverse circulation drill program. As of Sept. 25, 14 holes were completed in the drill program. The news release in Stockwatch Aug. 28 reported assay results for the first two drill holes, (98-114B and 98-113B). This release reports assay results from the subsequent five drill holes of the program. Assay data for the remaining drill holes are expected soon.

Average Assay Values

Primary
Mineralized
Drill Interval
Hole (thickness Cu Ni Co
No. in feet) (%) (%) ppm

98-105B ( 0- 25) 25 0.59 0.16 88.2

98-105B ( 35-115) 80 0.38 0.12 99.3

98-105B (160-195) 35 0.38 0.12 115.7

98-108B ( 20- 65) 45 0.42 0.15 80.5

98-108D ( 85-105) 20 0.36 0.12 60.7

98 86B (295-535) 240 0.48 0.14 80.2

98-201C (270-505) 235 0.43 0.13 71.1

98-210C (535-590) 55 0.35 0.11 75.1

98-113C (185-305) 120 0.39 0.15 118.9

Average Assay Values

Primary
Mineralized
Drill Interval
Hole (thickness Au Pt Pd
No. in feet) (g/t) (g/t) (g/t)

98 105B ( 0- 25) 25 0.065 0.119 0.538

98-105B ( 35-115) 80 0.058 0.090 0.279

98-105B (160-195) 35 0.036 0.060 0.169

98-108B ( 20- 65) 45 0.061 0.136 0.386

98-108B ( 85-105) 20 0.057 0.105 0.342

98-86B (295-535) 240 0.084 0.115 0.465

98-201C (270-505) 235 0.079 0.101 0.448

98-210C (535-590) 55 0.036 0.057 0.399

98-113C (185-305) 120 0.037 0.067 0.266


Both the thickness and grade of the mineralized interval in 98-105B and 98-108B are less than the values reported in Stockwatch Aug. 28 for holes 98-114B and 98-113B. Both of these holes occur on the northwest side of a fault. The relative movement on the fault brings the mineralized unit to the surface on the northwest side and down-drops it on the southeast side. (Note the shallow depth of mineralization in hole 98-105C, 0-195 feet, versus the depth of mineralization in hole 98-86B, 295-535 feet.) Erosion apparently has removed some of the mineralized thickness on the northwest side of the fault.
All material from this drill program is sampled every five feet and shipped to Acme Analytical Laboratories in Vancouver for assaying. Chemex Labs is conducting check assays.
Reverse circulation chips of average mineable grade identified from the assay results are being stored and will be sent to Lakefield Research Laboratories in Brampton, Ontario. The samples will be crushed, ground, and subjected to flotation to make a bulk sulphide concentrate. This concentrate will be shipped to different metallurgical labs for bio-leaching, pressure oxidation leaching, and other hydrometallurgical studies.

(c) Copyright 1998 Canjex Publishing Ltd. canada-stockwatch.com